Confidential Details of Adjustments 249 EPSON WF-6590/WF-6530/WF-6090 Series Revision C 3.2.3 Head Angular Mecha Adjustment The following explains the Head Angular Mecha Adjustment. Start method of the Maintenance SP Mode 1. Start the Maintenance SP Mode by turning it on with [No.6] button, [No.4] button, and [Power] button on the Panel simultaneously. Figure 3-21. Start method of the Maintenance SP Mode (1) „ When the Head angular mecha adjustment is performed, it is necessary to remove the ADF/Scanner Unit and the exterior parts from the product. However, fatal error occurs if the ADF/Scanner Unit is removes from product, and the printer is turned on. Therefore, make sure to start the printer by the “Maintenance SP Mode” when the Head angular mecha adjustment is performed. „ In case of the WF-6090 series, turn on them as usual because ADF/Scanner Unit is not supported for them, During the inspection Mode, operations such as menu selection can be done by pressing the following button on the panel. Figure 3-20. Panel Operation in Maintenance SP mode Power [3] Moves up menu selection. [6] Moves down menu selection. [Color] Enter Power button No.4 button No.6 button