Confidential Details of Adjustments 239 EPSON WF-6590/WF-6530/WF-6090 Series Revision C If the CR Unit does not touch the thickness gauge Start over from Step 4-1. Repeat the adjustment until the CR Unit touches the thickness gauge. Move the CR Unit back in the middle of the printer, and place the 1.25 mm-thick thickness gauge shown in Table 3-4 on position B in Figure 3-7 . 3. 4. Move the CR Unit to the thickness gauge and check whether the CR Unit touches the thickness gauge or not. If the CR Unit does not touch the thickness gauge Tighten the screw of the PG Adjustment Cam on the 0-digit side, and confirm the PG on the 0-digit side is appropriate according to the procedure in " Adjustment of the 0-digit side (p237)" , then go to "3.2.1.4 Checking the Platen Gap (p240)" . If the CR Unit touches the thickness gauge Rotate the PG Adjustment Cam on the 0-digit side by one notch in the - direction and check whether the CR Unit touches the thickness gauge or not (refer to Figure 3-6 ). Repeat the adjustment until the CR Unit does not touch the thickness gauge any more.