EPSON WF-6090,WF-6530, WF-6590 Series Service Manual Page 221-240

Confidential Details of Adjustments 236 EPSON WF-6590/WF-6530/WF-6090 Series Revision C † APG position check Confirm the APG position is set to [PG1]. „ Check method “1” on the CR Bearing is exactly on the bottom. Figure 3-5. APG position check If not, insert a pin or a similar tool into the hole on the CR Bearing and adjust it until “1” comes exactly on the bottom. † Position check of the PG Adjustment Lever Confirm the center of the notches on the PG Adjustment Lever located on the side of the printer is set to the rib on the frame. Figure 3-6. PG Adjustment Lever 1 CR Bearing Hole Left PG Adjustment Lever (130-digit side) Right PG Adjustment Lever (0-digit side) Rib Rib PG: Max. PG: Min. PG: Max. PG: Min.