EPSON WF-4830 Series/WF-4820 Series Revision A Disassembly/Assembly Routing FFCs/cables 146 Confidential FAX FFC Secure the ferrite core of the FAX FFC at the point shown above with double-sided tape. Secure the FAX FFC to the shield plate with double-sided tape. FAX FFC Ferrite core Double-sided tape Double-sided tape Acetate tape WF-4830 Series FAX FFC Ferrite core Double-sided tape Double-sided tape WF-4820 Series Speaker Cable Route the Speaker Cable between Head FFC and the housing, and route it though the ribs (x2) of the housing. Speaker Cable Head FFC Rib Housing Rib Rib Guide Rear ASF Upper Assy (Only for EAI) Put the ferrite core of the Power Supply Grounding Wire at the point shown above. Route the Power Supply Grounding Wire through the rib of the Guide Rear ASF Upper Assy. Route the Power Supply Cable (1) through the rib and hook of the Guide Rear ASF Upper Assy. Ferrite core Guide Rear ASF Upper Assy Power Supply Grounding Wire Power Supply Cable (1) Ribs Hook