Epson P5000,4900,4910 service manual Page 301-350

SC-P5000 Series/Epson Stylus Pro 4900/4910 Revision G DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 301 SE Group Confidential (Related Staff Only) 3.4.12.4 Drying Fan 1. Remove the Color Measurement Device. (p288) 2. Remove the Mounter. (p156) 3. Remove the Upper Cover. (p290) 4. Remove the I/F Cover. (p291) 5. Remove the Left Cover. (p293) 6. Disconnect the relay connector. 7. Release the harness from the clamp and the cable guide. 8. Remove the four screws that secure the Drying Fan. A) Silver, Phillips, Bind P-tite M2.6x12 (bit: No.1): four pieces 9. Remove the Drying Fan. Figure 3-225. Removing the Drying Fan When removing the screws in the next step, use a screwdriver whose shaft is 3.5 cm or longer. When securing the Drying Fan with the screws, first insert the screwdriver into the hole in front of the Drying Fan, and then set the screw to the driver. If it is difficult to secure the Drying Fan with the screws, remove the Rear Cover, and then secure with the screws. ( Step 8 to Step 9 in "3.4.12.8 CR Motor" (P. 308) ) When removing the Drying Fan in the next step, be careful not to damage the Thermistor. Make sure to route the harness correctly as shown in Figure 3-224 . Be sure to refer to Chapter 4 “Adjustment” (see p312) and perform specified adjustment after replacing or removing the Drying Fan. <Adjustment item> Spectroproofer Movement Check Relay connector Clamps Cable guide A Drying Fan Thermistor
Page 1 of 40

Epson SC-P5000 Series Service Repair Manual Page 301-350
Epson Stylus Photo Pro4900 Service Repair Manual Page 301-350
Epson Stylus Photo Pro4910 Service Repair Manual Page 301-350

Leave a Reply